Supported Metrics

The following tabs represent the Metric Category of HPE Performance Cluster Manager

Metric CategoryNative TypeNameDisplay NameUnitsDescription
UsageHPC Nodehpc_node_nfsMounts_AvailableHPC Node NFS Mounts AvailablecountProvides the count of available NFS Mounts
HPC Nodehpc_node_bond_err_inHPC Node Bonded Network Interface Errors InErrors per SecProvides the count of input errors on Bonded Network Interface
HPC Nodehpc_node_bond_err_outHPC Node Bonded Network Interface Errors outErrors per SecProvides the count of output errors on Bonded Network Interface
HPC Nodehpc_node_bond_inHPC Node Bonded Network Interface In trafficMBpsProvides the count of input traffic on Bonded Network Interface
HPC Nodehpc_node_bond_outHPC Node Bonded Network Interface out trafficMBpsProvides the out traffic on Bonded Network Interface
HPC Nodehpc_node_logins_countHPC Node Logins CountcountProvides the count of Node logins
PerformanceHPC Nodehpc_node_bufferCache_UtilizationHPC Node Buffer Cache Utilization%Provides the utilization of BufferCache
HPC Nodehpc_node_cpu_freequencyHPC Node CPU FreequencyMHzProvides the Freequency of CPU
HPC Nodehpc_node_cpu_loadHPC Node CPU Load%Provides the CPU load
HPC Nodehpc_node_diskReads_PersecHPC Node Disk Reads Per SecMBpsProvides the Disk Reads Per Sec
HPC Nodehpc_node_diskWrites_PersecHPC Node Disk Writes Per SecMBpsProvides the Disk Writes Per Sec
HPC Nodehpc_node_memory_usageHPC Node Memory Usage%Provides the used memory utilization
HPC Nodehpc_node_network_trafficInHPC Node Network Traffic InMBpsProvides the usage of network traffic In
HPC Nodehpc_node_network_trafficOutHPC Node Network Traffic OutMBpsProvides the usage of network traffic Out
HPC Nodehpc_node_pageCache_UsageHPC Node Page Cache Usage%Provides the usage of Page Cache
HPC Nodehpc_node_processMemory_usageHPC Node ProcessMemory Usage%Provides the usage of Process Memory
AvailabilityHPC Nodehpc_node_swapAvailable_mbHPC Node Available Swap MemoryMBProvides the available swap memory
HPC Nodehpc_node_uptime_InDaysHPC Node Uptime In DaysDaysProvides the Uptime in Days
PerformanceHPC Nodehpc_node_swapMemory_usageHPC Node Swap Memory Usage%Provides the usage of swap memory

Default Monitoring Configurations

HPE Performance Cluster Manager (HPCM) has default Global Device Management Policies, Global Templates, Global Monitors and Global metrics in OpsRamp. You can customize these default monitoring configurations as per your business use cases by cloning respective global templates and global Device Management Policies. OpsRamp recommends performing the below activity before installing the application to avoid noise alerts and data.

  1. Default Global Device Management Policies

You can find the Device Management Policy for each Native Type at Setup > Resources > Device Management Policies. Search with suggested name in global scope. Each Device Management Policy follows below naming convention:

{appName nativeType - version}

Example: hpe-performance-cluster-manager HPC Node - 1 (i.e, appName = hpe-performance-cluster-manage, nativeType = hpcm Node, version = 1)
  1. Default Global Templates

    You can find the Global Templates for each Native Type at Setup > Monitoring > Templates. Search with suggested names in global scope. Each template follows below naming convention:

    {appName nativeType 'Template' - version}

    Example: hpe-performance-cluster-manager HPC Node Template - 1 (i.e, appName = hpe-performance-cluster-manager, nativeType = HPC Node, version = 1)

  2. Default Global Monitors

    You can find the Global Monitors for each Native Type at Setup > Monitoring > Monitors. Search with suggested name in global scope. Each Monitors follows below naming convention:

    {monitorKey appName nativeType - version}

    Example: HPC Node Monitor hpe-performance-cluster-manager HPC Node - 1(i.e, monitorKey = hpcm-node Monitor, appName = hpe-performance-cluster-manager, nativeType = HPC Node, version = 1)